skip to Main Content
Menu

ISSUES WITH PLASTIC PRESSER

Plastic injection molding machine presses life products such as plastic chairs, plastic spoons, plastic cups and plastic components. The causes of plastic injection machine damage help customers understand and minimize the damage. An Huy Hydraulic provides top repair and maintenance services and equipment!

Possible causes of failures in the hydraulic system

When troubleshooting hydraulic systems, it should be remembered that pumps generate fluid flows. However, there must be resistance to the fluid flow to create pressure. The following lists hydraulic system performance problems and their respective possible causes that should be sought in troubleshooting:

plastic-injection-machine

plastic-injection-machine

1.Pump makes loud noise

  • Air enters the pump inlet
  • Pump shaft and drive motor shaft are not aligned
  • Oil viscosity too high
  • The filter on the inlet is dirty
  • Safety valve opens and closes unstable
  • Pump is broken
  • Pump rotation speed is too high
  • The suction line is loose or damaged

2. Low or erratic pressure

  • Gas contained in hydraulic oil
  • The opening pressure of the safety valve is set too low
  • Leaks in hydraulic pipes
  • Pump is worn or not sealed
  • The actuator is worn or not sealed

3. No pressure

  • Pump rotates in the wrong direction
  • Hydraulic line interrupted
  • Safety valve is always open due to stuck
  • Pump shaft broken
  • The entire pump flow flows to the tank because the valve, valve seat or actuator is damaged

4. Actuator does not move

  • Pump is broken
  • Distribution valve (direction control valve) does not move
  • System pressure is too low
  • The actuator is damaged
  • Safety valve is always open due to stuck
  • Actuator load is too large
  • Non-return valve installed

5. Actuator moves slowly or erratically

  • There is gas in the system
  • Liquid viscosity is too high
  • Pump is worn or damaged
  • Pump speed too low
  • Is there a leak through the actuator or through the check valve
  • The flow control valves are dirty or damaged
  • The vent in the oil tank (usually the oil filler cap) is sealed
  • Oil level in tank is too low
  • One-way valve is broken
  • Safety valve opens and closes unstable

6. The hydraulic oil in the system is too hot

  • The cooling unit is clogged or damaged
  • The equipment in the system or pipeline is too small
  • Incorrect hydraulic oil
  • Safety valve must operate continuously
  • The system is overloaded
  • Hydraulic oil is dirty
  • Oil tank too small
  • Pump rotation speed is too fast
  • Ventilation section is blocked or the size is not enough

AN HUY AUTOMATIC JOINT STOCK COMPANY
———————————————————————————
Address: 91 De La Thanh, O Cho Dua, Dong Da, Hanoi
Phone: 0977282045 – 0989257507
Website: https://anhuyautomatic.com.vn/
Email: anhuyhydraulic@gmail.com
———————————————————————————

Partner

Logo_Bosch_Rexroth

Hydro-Leduc

logo-Sauer-Danfoss

Vickers-logo

yuken-logo

0989.257.507

Back To Top
Copyright @ 2018 An Huy AUTOMATIC.JSC | Designed by: Web Bách Thắng